Pump-solutions-group Neptune Series 6000 dia-PUMP MODELS 6100 thru 6250 Manual de usuario

Busca en linea o descarga Manual de usuario para Zapatillas Pump-solutions-group Neptune Series 6000 dia-PUMP MODELS 6100 thru 6250. Pump Solutions Group Neptune Series 6000 dia-PUMP MODELS 6100 thru 6250 User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 27
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
ZL107602
for
NEPTUNE
SERIES 6000 “dia-PUMP”
MODELS 6100 thru 6250
Lansdale, PA. 19446 Tel.: 215-699-8700 FAX: 215-699-0370


Vista de pagina 0
1 2 3 4 5 6 ... 26 27

Indice de contenidos

Pagina 1

ZL107602 for NEPTUNE SERIES 6000 “dia-PUMP” MODELS 6100 thru 6250  Lansdale, PA. 19446

Pagina 2 - SAFETY INSTRUCTIONS:

10 Take out Relief Valve cap to access Relief Valve screw (#32 on Parts Drawing). Insert Hex wrench to adjust relief valve setting. FIGURE 2

Pagina 3

11 6.0 START UP PROCEDURE The following start up procedure is complete and does repeat instructions on filling the gearbox and pump. 6.0.1 Remov

Pagina 4

12 SECTION III NORMAL MAINTENANCE 7.0 MAINTENANCE Under normal conditions, the “dia-Pump” should not require any significant amount of maintenan

Pagina 5

13 7.1.5 Remove sealing nut (#39 on Parts Drawing) 7.1.6 Remove seal plate (#38 on Parts Drawing) using small brass hook to pry loose 7.1.7 Rep

Pagina 6

14SECTION V TROUBLE SHOOTING CHART SYMPTOMS CAUSES REMEDIES 1. Pump Motor Will Not Operate. A. Blown Fuse. Check for short circuit or overload

Pagina 7

15SECTION VI 9.0.1 SPARE PARTS 9.0.2 Important—When ordering spare parts, please show MODEL NUMBER AND SERIAL NUMBER of pump for which parts are b

Pagina 9

17PARTS LIST FOR PUMP MODELS 6100 to 6250 (REFER TO PART DRAWING ON PAGE 16) PARTS FOR PUMPS WITH METAL HEADS ITEM# DESCRIPTIO

Pagina 10

18SECTION VII SPECIAL INSTRUCTIONS FOR SERIES 6000 “dia-PUMPS” WITH ELECTRONIC STROKE CONTROL MODEL #SM-1020 Neptune Electronic Stroke Control U

Pagina 12

2 WARNING LOCKOUTS ARE REQUIRED BEFORE SERVICING THIS EQUIPMENT. SAFETY INSTRUCTIONS: Shut off/Lockout pump P

Pagina 14 - TROUBLE SHOOTING CHART

21SECTION IX DOUBLE DIAPHRAGM OPTION Special Instructions for Series 6000 “dia-Pumps” with Double Diaphragm The instructions below are for Neptun

Pagina 15

22 11.0.9 Remove the vacuum pump. Plug valve Item No. 5 with a 316SS pipe plug Item No. 12 (Figure 5) 11.0.10 Reinstall the Pump 11.0.11 Follow

Pagina 16

23 MSDS SECTION I - Material Identity Item Name... HYDRALIC LUBRICATING FLUID Part Number/Trade Name...

Pagina 17

24 SECTION IV - Fire and Explosion Hazard Data Flash Point Method... UNK Lower Explosion Limit... 1% Upper Expl

Pagina 18

25 SECTION VIII - Control Measures Respiratory Protection... NONE NEEDED UNDER ANTICIPATED USE W/ADEQUATE VENTILATION Ventilation..

Pagina 19

26NOTES:

Pagina 21

3 TABLE OF CONTENTS SECTION PARAGRAPH PAGE I GENERAL DESCRIPTION 4 LIMITED WARRANTY 5 PARTS ORDERING INSTRUCTIONS 6

Pagina 22 - Figure 5

4 SECTION I GENERAL DESCRIPTION The Neptune Series 6000 “dia-PUMP” is a reliable metering pump of the high-pressure diaphragm type. Under con

Pagina 23

5 SECTION I NEPTUNE CHEMICAL PUMP COMPANY LIMITED WARRANTY All Neptune Pumps are tested at the factory prior to shipment. Each part used in thei

Pagina 24

6 SECTION I PARTS ORDERING INSTRUCTIONS The complete model number and serial number of the pump must be furnished to insure prompt and accurate p

Pagina 25

7 SECTION II INSTALLATION INSTRUCTIONS 1.0 GENERAL (REFER TO PARTS DRAWING ON PAGE#16) 1.0.1 UNPACKING & INSPECTION When unpacking a pump

Pagina 26

81.0.8 Fill gearbox and pump by pouring the hydraulic fluid (drive lubricant) supplied through the fill opening at the rear of the pump. Pour fluid

Pagina 27

94.0.2 The internal relief valve is designed to protect the pump itself should a discharge pressure beyond the relief valve setting o

Comentarios a estos manuales

Sin comentarios